General Brackish Water ULP Series RO Membranes

//General Brackish Water ULP Series RO Membranes

General Brackish Water RO Membranes

General Brackish Water ULP Series RO Membranes

IonClear™ ULP series RO membranes are suitable for desalination treatment of water sources such as surface water, ground water, tap water and municipal water with a salt content below about 2000ppm. They are mainly used in various scales of pure water, boiler feed water, food processing and pharmaceutical manufacturing industries, etc. In this field, it can achieve the same high flux and high rejection rate as conventional low-pressure membranes under ultra-low operating pressure conditions. Its operating pressure is about 2/3 of that conventional low-pressure composite membranes, and the rejection rate can reach 99.5%, thereby reducing the investment costs of related pumps, pipelines, containers and other equipment and the operating costs of reverse osmosis systems, and improving economic benefits.

  • High flux and high rejection rate

  • Low operating cost, good economic benefits

Product Dimensions
Model
A inch (mm)
B inch (mm)
C inch (mm)
D inch (mm)
ULP-4040-82
37.9(963)
1.05(26.7)
0.75(19)
3.9(99)
ULP-8040-400
40 (1,016)
/
1.125(29)
7.9(201)
ULP-8040-440
40 (1,016)
/
1.125(29)
7.9(201)
Product Specifications
Model
Effective Membrane ft² (㎡)
Stabilized Rejection Rate(%)
Minimum Rejection Rate(%)
Flux, gpd (m³/d)
ULP-4040-82
82(7.6)
99.50
99.0
2250(8.6)
ULP-8040-400
400(37.2)
99.50
99.0
11350(43)
ULP-8040-440
440(41)
99.50
99.0
12650(48)

Flux and rejection rate is based on the following standard test conditions: 1.03 MPa (150 psi) pressure, 77°F (25°C), 1500 ppm NaCl solution and pH 8 for feedwater, and 15% recovery.

Operating and Cleaning Limits
  • Maximum Operating Pressure                41 bar (600 psi)
  • Maximum Operating Temperature        45°C (113°F )
  • Maximum Element Pressure Drop         1.0 bar (15psi)
  • pH Range Continuous Operation            2-11
  • pH Range Short-Term Cleaning               1-13
  • Maximum Feed SDI(SDI )                         5.0
  • Free Chlorine Tolerance                            < 0.1 ppm
Notes
  • Permeate flow for individual elements may vary ±15 percent from the value specified.
  • Active membrane area guaranteed ±4%.
  • Stabilized salt rejection is generally achieved within 24-48 hours of continuous use; depending upon feedwater characteristics and operating conditions.